1.1. Scope
The purpose of this document is to recommend mechanical and electrical standards for 75 ohm broadband radio frequency (RF) devices whose purpose is to provide an outdoor inline connection between two type “F” male connectors that conform to ANSI/SCTE 123; Specification for “F” Connector, Male, Feed-Through or ANSI/SCTE 124; Specification for “F” Connector, Male, Pin Type and ANSI SCTE 160,Specification for Mini F connector male Pin type. The mechanical configuration is designed to accommodate sealing rings for external applications.
This specification is not intended to restrict any manufacturer’s innovation and improvement. The
specification may be amended in the future as deemed appropriate.
2. Informative References
The following documents might provide valuable information to the reader but are not required when
complying with this document.
2.1. SCTE References
– ANSI/SCTE 123 Specification for “F” Connector, Male, Feed-Through
– ANSI/SCTE 124, Specification for “F” Connector, Male, Pin Type
– ANSI/SCTE 144, Test Procedure for Measuring Transmission and Reflection
– ANSI/SCTE 04, Test Method for “F” Connector Return Loss
– ANSI/SCTE 48-1, Test Method for Measuring Shielding Effectiveness of Passive and Active Devices Using a GTEM Cell
– ANSI/SCTE 103, Test Method for DC Contact Resistance, Drop Cable to F- Connectors and F81 Barrels
– ANSI/SCTE 143, Test Method for Salt Spray
– ANSI/SCTE 81 Surge Withstand Test Procedure
2.2. Standards from Other Organizations
– No informative references are applicable.
2.3. Published Materials
– No informative references are applicable.
3. Compliance Notation
shall This word or the adjective “required” means that the item is an absolute requirement of this document. shall not This phrase means that the item is an absolute prohibition of this document. forbidden This word means the value specified shall never be used. should This word or the adjective “recommended” means that there may exist valid reasons in particular circumstances to ignore this item, but the full implications should be understood and the case carefully weighted before choosing a different course. should not This phrase means that there may exist valid reasons in particular circumstances when the listed behavior is acceptable or even useful, but the full implications should be understood and the case carefully weighed before implementing any behavior described with this label. may This word or the adjective “optional” means that this item is truly optional. One vendor may choose to include the item because a particular marketplace requires it or because it enhances the product, for example; another vendor may omit the same item. deprecated Use is permissible for legacy purposes only. Deprecated features may be removed from future versions of this document. Implementations should avoid use of deprecated features.
4. Mechanical
4.1. Dimensions
The physical dimension of the inline splice shall meet the dimensional requirements of Figure 1.
4.2. Center Conductor Mating
The center conductor contact of both ends shall accept male “F” connector center conductors whose
diameters are between 0.0250” (0.64 mm) diameter and 0.0420” (1.07 mm) diameter. The junction shall have a minimum retention force of 50 grams with a 0.0320” (0.812 mm) diameter conductor inserted after the contact is mated 25 times with a center conductor whose diameter is 0.0403” (1.02 mm) when tested in accordance to IPS TP 417, Test Method for F Connector Center Conductor Retention.
5. Electrical
5.1. Bandwidth
Bandwidth shall be a minimum of 5 MHz to 1,218 MHz.
Unless otherwise specified, all performance parameters listed shall be tested in this frequency range.
5.3. Return Loss
Shall be no worse than 30 dB, when tested in accordance to ANSI/SCTE 04, ANS Test Method for ”F”
Connector Return Loss or ANSI/SCTE 144 Procedure for Measuring Transmission and Reflection.
5.4. Shielding Effectiveness
The shielding effectiveness of the assembled components shall be a minimum of 100dB, when tested in accordance with ANSI/SCTE 48-1, Test Method for Measuring Shielding Effectiveness of Passive and Active Devices Using a GTEM Cell.
5.5. Surge Withstand
The surge withstand when measured in accordance with ANSI/SCTE 81 shall be a minimum of IEEE
C62.41-1991 Category A3 Ring Wave, 6KV, 200 Amps.